One Corner of
lithium battery drying chamber
(Hitachi Maxell, first phase) |
¡¡ |
ZHS-¡õ-SDP
ultra-low drew point
dehumidifying and drying
system(temperature 20¡«25¡æ,
relative humidity, 0.1¡«5%RH,drew
point£75¡ædp,
wind rate processing capacity:
300¡«30000m3/h) |
|
 |
¡¡ |
 |
|
Drew point
display value of lithium battery
drying chamber (Hitachi Maxell) |
¡¡ |
Lithium battery
drying chamber in use (Hitachi
Maxell, first phase) |
 |
¡¡ |
 |
|
Machine room
(Hitachi Maxell, second phase) |
¡¡ |
Machine room
(Hitachi Maxell, Japan. At the
left is the second phase machine
set and right is the first phase
machine set) |
 |
¡¡ |
 |
|
Drew point |
¡¡ |
Drying chamber
(Hitachi Maxell, second phase) |
 |
¡¡ |
 |
|
Drying chamber
and glove-box (McNair
High-tech Co., Ltd) |
¡¡ |
Drying chamber
and glove-box (McNair
High-tech Co., Ltd) |
 |
¡¡ |
 |
|
Drew point inside
of drying chamber |
¡¡ |
Machine set |
 |
¡¡ |
 |
|
Drying chamber (McNair
High-tech Co., Ltd) |
¡¡ |
Drying chamber (BAK
Battery) |
|
¡¡ |
¡¡ |
¡¡ |
|
Item |
Operator |
Wind rate
processing capacity |
Recovery
Method*
|
Recovery
Method(Electric) |
Cooling
load |
Dehumidifying
space
|
Power of
refrigerator
|
|
person |
m3/h |
KW |
KW |
KW |
m3 |
KW |
|
ZHS-450 |
1¡«3 |
500¡«800 |
9¡«13 |
19¡«32 |
38¡«92 |
25¡«40 |
12.5¡«30.4 |
|
ZHS-550 |
2¡«4 |
800¡«1000 |
11¡«18 |
27¡«43 |
56¡«187 |
40¡«60 |
18.5¡«51 |
|
ZHS-770 |
3¡«5 |
1500¡«2800 |
7.5 |
66¡«98 |
92¡«220 |
60¡«90 |
30.4¡«66 |
|
ZHS-950 |
4¡«8 |
2800¡«4000 |
11¡«15 |
82¡«130 |
110¡«260 |
90¡«150 |
36.4¡«78 |
|
ZHS-1200 |
10¡«20 |
4000¡«6000 |
19¡«27 |
£ |
180¡«430 |
100¡«230 |
54¡«129 |
|
ZHS-1500 |
18¡«40 |
7000¡«10000 |
31¡«48 |
£ |
228¡«640 |
230¡«370 |
68.5¡«192 |
|
ZHS-1900 |
50¡«80 |
9000¡«15000 |
39¡«55 |
£ |
390¡«1425 |
370¡«500 |
117¡«426 |
|
ZHS-2400 |
100¡«150 |
12000¡«20000 |
50¡«72 |
£ |
700¡«1600 |
500¡«670 |
210¡«480 |
|
ZHS-3000 |
200¡«250 |
18000¡«30000 |
90¡«110 |
£ |
870¡«2350 |
670¡«830 |
261¡«705 |
|
|
¡¡ |
|
Note:
1.wind
speed of rotary wheel surface:
m/S design
2.To
ensure the normal breath of
operators and plus pressure of
drying chamber, supplying new
air should be calculated by
20~30m/h per person, plus
pressure should be calculated by
the times of drying chamber
area, and take the max. value of
them. Outside air condition is
36¡æ,relative
humidity 70%, absolute moisture
content 26.8g/kg dry air.
3.Moisture
load of operator calculated by
g/h. Before entering into drying
chamber the operators should
come to buffer chamber.
4.The
recovery method* can select and
use steam, fuel oil, natural
gas, liquefied gas, and city
gas.
5.Power
of dehumidify fan and air
blow-in fan is not contained in
the power of ZHS-770~ZHS-3000
rotary dehumidifier. Power
supply: three phase 380V50HZ.
6.The
outline dimension of machine set
can be verified by the actual
needs of users.
7.Because
of the continual development of
technology, the actual technical
parameters should be in
accordance with the altered
parameters. |